Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-12 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	67
Date	08/12/14
Start Time	11:45:30
Diameter Midpoint
 10.9	11541
 11.3	102600
 11.8	107393
 12.2	44835.5
 12.6	26868.4
 13.1	15402.3
 13.6	8404.2
 14.1	5063.4
 14.6	2756.85
 15.1	991.577
 15.7	878.444
 16.3	209.275
 16.8	154.759
 17.5	105.112
 18.1	76.3677
 18.8	97.0407
 19.5	61.1919
 20.2	161.465
 20.9	104.125
 21.7	133.715
 22.5	204.547
 23.3	126.658
 24.1	109.175
 25.0	104.122
 25.9	106.487
 26.9	80.6559
 27.9	0.374908
 28.9	33.9282
 30.0	0
 31.1	7.67701
 32.2	0
 33.4	0
 34.6	31.5824
 35.9	117.226
 37.2	672.884
 38.5	1497.69
 40.0	2313.38
 41.4	2592.51
 42.9	2732.9
 44.5	2746.09
 46.1	2592.13
 47.8	2285.87
 49.6	1820.89
 51.4	1502.83
 53.3	1084.77
 55.2	717.523
 57.3	329.463
 59.4	62.2004
 61.5	0
 63.8	0
 66.1	0
 68.5	0
 71.0	0
 73.7	488.255
 76.4	1130.43
 79.1	1774.22
 82.0	2012.71
 85.1	2632.2
 88.2	3136.95
 91.4	3357.03
 94.7	3369.68
 98.2	3417.24
101.8	3072.27
105.5	2890.84
109.4	2539.82
113.4	2020.71
117.6	1549.38
121.9	1350.5
126.3	1039.9
131.0	779.331
135.8	531.436
140.7	458.607
145.9	374.81
151.2	232.729
156.8	132.121
162.5	128.881
168.5	82.112
174.7	60.6295
181.1	37.1689
187.7	40.5368
194.6	33.3997
201.7	28.2329
209.1	16.9045
216.7	17.7266
224.7	17.5403
232.9	17.5535
241.4	16.1667
250.3	10.3089
259.5	18.6993
269.0	3.37205
278.8	8.17414
289.0	12.789
299.6	16.9024
310.6	5.38152
322.0	5.65244
333.8	6.91427
346.0	4.26726
358.7	2.1707
371.8	1.38521
385.4	3.08814
399.5	2.27625
414.2	0
429.4	0
445.1	0
461.4	2.44135
478.3	4.98215
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.1455
High Voltage	9879.34
Lower Size(nm)	10.7461
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1076.23
Median(nm)	11.8694
Mean(nm)	22.901
Geo. Mean(nm)	15.9561
Mode(nm)	11.7574
Geo. Std. Dev.	1.99752
Total Concentration(#/cm)	390608
Comment	
